Manual rotary high pressure steam sterilizer PMJ series
Manual rotary high pressure steam sterilizer PMJ series
Manual rotary high pressure steam sterilizer PMJ series
Manual rotary high pressure steam sterilizer PMJ series
Manual rotary high pressure steam sterilizer PMJ series
Manual rotary high pressure steam sterilizer PMJ series
Related products
  • Product features
  • Technical parameter
  • Options and accessories
  • External removable pressure gauge for easy verification
    USB as standard


    peculiarity
    - Sterilization temperature can be set up to 138 degrees

    - PT1000 sensor, more accurate temperature control, display accuracy of 0.1 degrees

    - Standard double electrode water level sensor, real-time water level monitoring

    - With a 5-level password setting function (optional), it can be used for data traceability of pharmaceutical factories, in line with GMP and FDA certification requirements, and can print F0 values

    - SMS alarm (optional)

    - Gauges with negative pressure up to 0.5 display can be configured, overcurrent, short circuit protection system.

    - Standard with optimized function to prevent dry burning, overtemperature protection system, overpressure protection safety valve.

    - Open cover to stop heating function

    - Real-time data saving function, memory storage 20 programs, programmable sterilization programs of various modes

    - After the completion of sterilization, the exhaust valve can be discharged according to the set ten-stage exhaust speed, and the exhaust speed can be manually adjusted at any time during the exhaust process.

    --Freertos embedded operating system

    - Standard USB flash drive real-time data recording function

    - Automatic fault monitoring, alarm and recording function (optional printer required), anti-burn safety protection.

    - With automatic detection, check and compare the functional relationship between temperature and pressure to ensure that the true saturated steam state is achieved

    - Automatic detection of cold air discharge to ensure steam internal discharge function, to ensure a pollution-free environment

    - Boiling point temperature can be set according to altitude

    - The exhaust temperature can be adjusted within the boiling point temperature plus 0~25 degrees

    - Dual temperature sensors that can detect air and water temperature

    - One item sensor hole in the lid and two verification holes in the tank body are reserved for easy verification of the connection

    - Self-sensing pressure interlocking device closed cover inspection system, leakage protection device

     

    4. Large diameter, large capacity, sterilizer

    Product characteristics

    Liner diameter 370/400(110 L)

    Volume 50L / 65L/85L/110L

    Internal discharge (optional model) : After cooling, the steam is discharged through a professional condenser to achieve real internal discharge and eliminate environmental pollution

    Drying function (optional model) : After the sterilization of internal pressure drainage, through the external cavity heating mode for temperature drying

    Cooling fan: automatic start at the end of sterilization, optimized design of three-dimensional condensing fan to blow the whole inner tank, shorten the cooling time

     

    Display temperature accuracy: 0.1 degrees

    Sterilization stage graphic display, easy to view the sterilization process

     

    Inner liner polishing: Inner liner polishing, reduce bacterial adhesion area, prevent dirt residue, easy to clean and maintain users

    Dry burning protection: Standard dual electrode low water level sensor and heating rate software program, double overtemperature protection, effectively prevent dry burning

    Optional high efficiency filter: Equipped with 0.2um HEPA college filter, with bacteria filtration function, truly achieve zero pollution

     

    Many advantages Sterilization is safer and more thorough

    The take-off pressure of the safety valve is 0.28Mpa

    The maximum design pressure of sterilization pot is 0.3Mpa

     

    Pressure interlocking mechanism

    - Boot, sterilization start, the sterilization process of the micro position switch real-time monitoring of the location of the chain mechanism, once there is an abnormal alarm to stop to ensure safety.

    - Sterilization process As long as the open lid knob is rotated, the sterilization pot automatically alarms and stops

    - If the lid is not covered, the sterilizer automatically alarms and stops as long as the lid girder is moved during the sterilization process

    - Specially designed girder locking mechanism, sterilization process ensures that the lid cannot be opened, more safe and reliable

    After sterilization, the temperature in the cavity is lower than 95℃, and the opening temperature can be arbitrarily set.

    - Double overpressure protection

    - Double overtemperature protection

    - Double limit protection

    - Prevent dry burning

    - Pressure sensor

    - Leakage protector

    - Automatic intelligent control system

    option

    - Printer (printing content: internal pressure, sterilization temperature and time in the sterilization pot)

    - Item sensor

    -3Q authentication

    返回
    Contact
    Office
    Add:Block B, Floor 1, Building 1, No. 1918 Xupan Road,
    Xuhang Town, Jiading District, Shanghai
    Tel:+86-21-59906210 / 59906953 / 59906562
    After-sales service hotline: 4006806596
    Wechat: A19102167286
    E-mail:stik@stik.cn
    Mobile
    Purchase
    mobile
    Copyright (C) 2020,STIK Instrument Equipment Co., Ltd. All Rights Reserved.Supported by ChemNet ChinaChemNet Toocle 31fabu Copyright Notice