External removable pressure gauge for easy verification
USB as standard
peculiarity
- Sterilization temperature can be set up to 138 degrees
- PT1000 sensor, more accurate temperature control, display accuracy of 0.1 degrees
- Standard double electrode water level sensor, real-time water level monitoring
- With a 5-level password setting function (optional), it can be used for data traceability of pharmaceutical factories, in line with GMP and FDA certification requirements, and can print F0 values
- SMS alarm (optional)
- Gauges with negative pressure up to 0.5 display can be configured, overcurrent, short circuit protection system.
- Standard with optimized function to prevent dry burning, overtemperature protection system, overpressure protection safety valve.
- Open cover to stop heating function
- Real-time data saving function, memory storage 20 programs, programmable sterilization programs of various modes
- After the completion of sterilization, the exhaust valve can be discharged according to the set ten-stage exhaust speed, and the exhaust speed can be manually adjusted at any time during the exhaust process.
--Freertos embedded operating system
- Standard USB flash drive real-time data recording function
- Automatic fault monitoring, alarm and recording function (optional printer required), anti-burn safety protection.
- With automatic detection, check and compare the functional relationship between temperature and pressure to ensure that the true saturated steam state is achieved
- Automatic detection of cold air discharge to ensure steam internal discharge function, to ensure a pollution-free environment
- Boiling point temperature can be set according to altitude
- The exhaust temperature can be adjusted within the boiling point temperature plus 0~25 degrees
- Dual temperature sensors that can detect air and water temperature
- One item sensor hole in the lid and two verification holes in the tank body are reserved for easy verification of the connection
- Self-sensing pressure interlocking device closed cover inspection system, leakage protection device
4. Large diameter, large capacity, sterilizer
Product characteristics
Liner diameter 370/400(110 L)
Volume 50L / 65L/85L/110L
Internal discharge (optional model) : After cooling, the steam is discharged through a professional condenser to achieve real internal discharge and eliminate environmental pollution
Drying function (optional model) : After the sterilization of internal pressure drainage, through the external cavity heating mode for temperature drying
Cooling fan: automatic start at the end of sterilization, optimized design of three-dimensional condensing fan to blow the whole inner tank, shorten the cooling time
Display temperature accuracy: 0.1 degrees
Sterilization stage graphic display, easy to view the sterilization process
Inner liner polishing: Inner liner polishing, reduce bacterial adhesion area, prevent dirt residue, easy to clean and maintain users
Dry burning protection: Standard dual electrode low water level sensor and heating rate software program, double overtemperature protection, effectively prevent dry burning
Optional high efficiency filter: Equipped with 0.2um HEPA college filter, with bacteria filtration function, truly achieve zero pollution
Many advantages Sterilization is safer and more thorough
The take-off pressure of the safety valve is 0.28Mpa
The maximum design pressure of sterilization pot is 0.3Mpa
Pressure interlocking mechanism
- Boot, sterilization start, the sterilization process of the micro position switch real-time monitoring of the location of the chain mechanism, once there is an abnormal alarm to stop to ensure safety.
- Sterilization process As long as the open lid knob is rotated, the sterilization pot automatically alarms and stops
- If the lid is not covered, the sterilizer automatically alarms and stops as long as the lid girder is moved during the sterilization process
- Specially designed girder locking mechanism, sterilization process ensures that the lid cannot be opened, more safe and reliable
After sterilization, the temperature in the cavity is lower than 95℃, and the opening temperature can be arbitrarily set.
- Double overpressure protection
- Double overtemperature protection
- Double limit protection
- Prevent dry burning
- Pressure sensor
- Leakage protector
- Automatic intelligent control system
option
- Printer (printing content: internal pressure, sterilization temperature and time in the sterilization pot)
- Item sensor
-3Q authentication