- Sterilization temperature can be set up to 138 degrees
-Adopt PT1000 sensor for more precise temperature control with 0.1 degree display accuracy
- Two water level monitoring functions: capacitive water level sensor and temperature type water level sensor
- With 5-level password setting function, it can be used for data trace of pharmaceutical companies, meet GMP and FDA certification requirements, and can print FO value.
-SMS alarm (optional)
-Configurable negative pressure to a pressure gauge up to 0.5Mpa
- Standard optimization to prevent dry burning
-Open the cover to stop heating
- Real-time data saving function, memory storage 60 programs, programmable various mode sterilization programs
- voice prompt function
-Intelligent multi-stage exhaust function
-Freertos embedded operating system
- Standard U disk real-time data recording and download function
-Log function (touch screen)
- Fault monitoring, alarm and recording functions (touch screen)
- With automatic detection, check the relationship between temperature and pressure to ensure a true saturated steam state
-Automatically detect cold air emissions, ensure steam internal discharge function, and ensure pollution-free environment
-The boiling temperature can be adjusted according to the altitude
- Exhaust gas temperature can be adjusted within 0-25 degrees of boiling temperature
- Dual temperature sensor for detecting temperature and water temperature
- One sensor hole and one verification hole for the tank cover, convenient for verifying the connection
|
Product advantages |
|
Inner row After cooling, the steam is discharged through a professional condenser to achieve true internal discharge and prevent environmental pollution.
cooling fan Automatic start of sterilization, optimized design of the three-dimensional condensing fan to the overall cooling of the liner, shortening the cooling time
|
Easy to operate:
Display accuracy:
0.1 sterilization stage graphic display The opening temperature can be adjusted according to the customer's demand below 95 °C. |
Internal electrochemical polishing:
Electrochemical polishing after blasting the inner liner to reduce the area of bacterial adhesion, anti-fouling residue, convenient for users to clean and maintain |
Dry burning protection:
Standard low water level sensor and heating rate software program to effectively prevent dry burning |
High efficiency filter:
0.2um HEPA college filter with filter function to achieve zero pollution |
Many advantages, sterilization is safer and more thorough
STIK provides you with high quality sterilizers, always adhering to the "safety first" purpose
Safety
Pressure chain - Start-up, sterilization start, micro-motion position switch in real-time during sterilization Monitor the location of the chain office to ensure safety once there is an abnormal alarm. - As long as there is pressure in the chamber (with pressure sensor), the lid cannot be opened. - The lid cannot be opened when the power is suddenly turned off during the sterilization process. - After the sterilization is completed, the opening temperature can be arbitrarily set within the chamber temperature below 95 °C. |
-Double overpressure protection -Double over temperature protection -Double exhaust solenoid valve - Prevent dry burning -Pressure Sensor -leakage protector -Full automatic intelligent control system |
|
Capacity (L) / model | Diameter 370 standard | Diameter 450 standard | Automatic hydration type | Dry type | Deodorizing type | Leading touch screen |
54 liters | IMJ-54A | |||||
78liters | IMJ-78A | |||||
65liters | IMJ-65A | MJ-65W | IMJ-65D | IMJ-65S | IMJ-65DT | |
85liters | IMJ-85A | MJ-85W | IMJ-85D | IMJ-85S | IMJ-85DT | |
100liters | IMJ-100A | IMJ-100W | IMJ-100D | IMJ-100S | IMJ-1000T | |
120liters | IMJ-120A | IMJ-120W | IMJ-120D | IMJ-120S | IMJ-1200T | |
Inner tube electropolishing | Have | Have | Have | Have | Have | Have |
Liner material | 3 | 3 | 3 | 3 | 3 | 3 |
Display accuracy | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 |
Sterilization maximum setting temperature | 138 | 138 | 138 | 138 | 138 | 138 |
Gas cylinder | Side setting | Side setting | Inside setting | Inside setting | Inside setting | Inside setting |
Sterilization range (°) | 105-138 | |||||
Dissolution temperature (°) | 50-100 | |||||
Holding temperature (°) | 40-60 | |||||
Set time | Sterilization, melting: 0 minutes - 9999 minutes; holding time: 9999 hours; scheduled sterilization time: 0-15 days delay | |||||
Storage System | ||||||
Pressure display range | -0.1-0.5mpa | |||||
Exhaust method | Full row, micro row, no row, intelligent multi-stage exhaust | |||||
Safety equipment | Pressure safety valve, prevent dry burning, door lock safety interlock device, chamber cover closing detection system, over pressure detection, over temperature detection, leakage short circuit detection | |||||
Automatic hydration | No | No | Have | Have | Have | Have |
Dry | No | No | No | Have | No | Have |
Internal row function | No | No | No | No | Have | Have |
Deodorization system | No | No | No | No | Have | Have |
Cooling fan | Horizontal row | Vertical row | Vertical row | Vertical row | Vertical row | Vertical row |
Water level sensing | Have | Have | Have | Have | Have | Have |
Pressure Sensor | Have | Have | Have | Have | Have | Have |
USB | Have | Have | Have | Have | Have | Have |
Pan opening method | One-touch upper cover | |||||
Dimensions(W*D*H)mm | 612*520*840 612*520*1070 815*660*985 815*660*1125 815*660*1230 815*660*1365 | |||||
Dimensions | 5-45℃ | |||||
Volume (liter) | 54 | 78 | 65 | 85 | 100 | 120 |
Rated power | 2800W | 3500W | 3500W | 4800W | 4800W | 4800W |
Sterilization bile size (diameter * high) | Φ370*508 | Φ370*730 | Φ450*465 | Φ450*605 | Φ450*710 | Φ450*845 |
Basket size(W*D*H)mm | Φ340*190*2 | Φ340230 Φ340*350 |
Φ430*190*2 | Φ430*230*2 | Φ430*230 Φ430*350 |
Φ430*350*2 |
Product weight | 79KG | 120kg | 110kg | 145kg | 180kg | 216kg |
Overall dimensions (W * D * H) mm |
612*520*840 | 612*520*1070 | 815*660*985 | 815*660*1125 | 815*660*1230 | 815*660*1365 |
Working power | 220V±10%,16A,50HZ/60HZ | 220V±10%,32A,50HZ/60HZ |
-The test technical data is only applicable to the test results under the no-load condition of the equipment and the ambient temperature is 25 degrees!
-The appearance and parameters of the product are subject to change without notice. The appearance of the product may vary due to photography and printing. Please understand!
-Printer (printing content: pressure in the pot during sterilization, sterilization temperature and time)
- item sensor
-3Q certification
-All internal rows